Many people will install the access control system, but because the installation is relatively simple, many people will choose to install it by themselves. In addition to the official installation method, there are still many precautions that many people do not know during the installation of the access control system.
1. Precautions for the installation location of each equipment in the access control system
Card reader: Do not install it on a metal object, the distance between two card readers should not be less than 30 cm, and it is best to supply power through the controller.
Network adapter: The connection with the controller is in a hand-in-hand way.
Controller: A controller without isolation, it is recommended to use the same power supply.
Lock: When installing the magnetic lock, it is necessary to make the lock body and the relay iron plate tightly combined, otherwise there will be insufficient suction. Electric mortise lock, if you need to open the socket when installing the electric mortise lock, pay attention to the hole diameter must be large enough, and the depth must be deep enough to allow the lock tongue to be fully inserted.
2. Precautions for the installation of each equipment of the access control system
Power supply: Ensure that the power is sufficient, try to use a linear power supply, and the door lock and controller should be powered separately. The power supply should be installed as close as possible to the electrical equipment to avoid interference and transmission loss.
Cablaggio: è suddiviso in linee elettriche, linee di comunicazione e linee di segnale. Durante il cablaggio, prestare attenzione a separare le linee forti e deboli. La distanza tra i due tubi deve essere maggiore di 20 cm.
Cavo di alimentazione: il diametro del filo è abbastanza spesso, utilizzando fili a più trefoli.
Linea di segnale e linea di comunicazione: utilizzare cinque tipi di doppino intrecciato schermati. Tra questi, il bus 485 deve essere collegato con un doppino intrecciato. Quando si acquistano cavi, si consiglia di utilizzare cavi schermati a quattro conduttori 4*0,5.
Autore: Scritto da Ms.Vivian He di S4A INDUSTRIAL CO., LIMITED
Factory Address:Building S4A, South Third Lane, Qiuyuling Street, Zhangkeng Village, Hengli Town, Dongguan City, Guangdong Province Office Address:#601,floor 6 ,building 1,JINFANGHUA industrial zone, Bantian St. Longgang Dist. Shenzhen, PRC.
se sei interessato ai nostri prodotti e vuoi conoscere maggiori dettagli, lascia un messaggio qui, ti risponderemo il prima possibile.